Viking Electronics LDB-3 Advanced Loop/Ring Detect Board for Ring and Line In Use Contact Closures
Description
Provide a Contact Closure during Ringing and/or Off-Hook
Ideal for Use with Two-Button Emergency Phones!
The LDB-3 Advanced Loop Detector monitors an analog phone line for ringing or an off hook condition. A built-in relay can be activated when either of these conditions are detected. This is ideal for monitoring line status or for providing a visual indication of such.
The LDB-3s disable input is ideal for two-button emergency phones, such as Vikings E-1600-20A, allowing "Info" button calls to be placed without activating the relay (turning on the emergency strobe light, camera, etc.)
Three DIP switches are provided for turning ring detection on or off, off-hook loop detection on or off and for selecting a ring cadence mode which allows the relay to follow ringing or to remain activated during the off time of standard ring cadence.
The LDB-3 comes complete with a 12 VDC power adapter, and can also provide switched 12VDC .35 Amp output to power external lights, etc. during ringing and/or off-hook conditions.
Control a strobe or beacon light for ring indication
Provide relay closures on off-hook
Trigger a security camera
Trigger a tape recorder
Phone "In Use" indicator
"Dead Line" detector
Detects ring voltage and off hook loop current
On/off switches for ring detection and off hook/loop detection
Screw terminal connections
Selectable ring cadence mode (relay can remain on between rings)
Wall mountable with foam tape (included) or screws (not included)
Switched 12V DC output (follows relay activation for powering strobe lights, cameras, etc.)
One set of (NO) normally open and (NC) normally closed relay contacts provided
Disable input, ideal for use with two-button emergency phones (E-1600-20A), will not activate relay on "Info" calls
Made in the USA
1 Year Warranty
Power: 120V AC to 12V DC adapter provided
Dimensions: 74mm x 53mm x 25mm (2.9" x 2.1" x 1.0")
Shipping Weight: 0.4 kg (0.86 lbs)
Environmental: -26° C to 54° C (-15° F to 130° F) with 5% to 95% non-condensing humidity
Relay Contact Rating: .5A @ 125V AC/1A @ 30V DC
Maximum Current Draw Auxiliary 12V DC Output: 350mA
Minimum Loop Current: 15 mA
Disable/Info Switch Input: 50mA/80mW maximum
Ringer Equivalence: 0.5 A REN
Connections: 10 pin screw terminal block